Selective methodology employing a tandem quadrupole mass spectrometer coupled to a gas chromatograph with headspace autosampler (HS-GC-MS/MS) was elaborated in this study. Application of the elaborated procedure resulted in a limit of detection of 0.021μgkg(-1) and a limit of quantification of 0.071μgkg(-1). The mean recoveries during in-house validation ranged from 89% to 109%, and coefficients of variation for repeatability ranged from 4% to 11%. The proposed analytical method was applied for monitoring the furan content of 30 commercial baby food samples available on the Latvian retail market. The level of furan found in these samples varied from 0.45 to 81.9μgkg(-1), indicating that infants whose sole diet comprises baby food sold in jars and cans are exposed constantly to furan. Samples containing vegetables and meat had higher levels of furan than those containing only fruits.
Keywords: Baby food; Furan; Tandem mass spectrometry.
Copyright © 2016 Elsevier Ltd. All rights reserved.