Machined versus roughened immediately loaded and finally restored single implants inserted flapless: Preliminary 6-month data from a split- mouth randomised controlled trial

Eur J Oral Implantol. 2016;9 Suppl 1(2):155-63.

Abstract

Purpose: To compare the outcome of immediately loaded single implants with a machined or a roughened surface.

Materials and methods: Fifty patients had two implant sites randomly allocated to receive flaplessplaced single Syra implants (Sweden & Martina), one with a machined and one with a roughened surface (sand-blasted with zirconia powder and acid etched), according to a split-mouth design. To be loaded immediately, implants had to be inserted with a torque superior to 50 Ncm. Implants were restored with definitive crowns in direct occlusal contact within 48 h. Patients were followed for 6 months after loading. Outcome measures were prosthetic and implant failures and complications.

Results: Two machined implants and four roughened implants were not loaded immediately. Six months after loading no dropout occurred. One implant loaded late, which had a rough implant surface, failed 20 days after loading (P (McNemar test) = 0.625; difference in proportions = -0.04; 95% CI: -0.15 to 0.07). Three crowns had to be remade on machined implants and four on roughened implants (P (McNemar test) = 1.000; difference in proportions = -0.02; 95% CI: -0.12 to 0.08). Three machined and five roughened implants experienced complications (P (McNemar test) = 0.625; difference in proportions = -0.04; 95% CI: -0.15 to 0.07). There were no statistically significant differences between groups for crown and implant losses as well as complications.

Conclusions: Up to 6 months after loading both machined and roughened flapless-placed and immediately loaded single implants provided good and similar results, however, longer follow-ups are needed to evaluate the long-term prognosis of implants with different surfaces.

Publication types

  • Comparative Study
  • Randomized Controlled Trial

MeSH terms

  • Acid Etching, Dental / methods
  • Adult
  • Crowns
  • Dental Etching / methods
  • Dental Implant-Abutment Design
  • Dental Implants, Single-Tooth*
  • Dental Materials / chemistry
  • Dental Prosthesis Design*
  • Dental Prosthesis, Implant-Supported*
  • Dental Restoration Failure
  • Female
  • Follow-Up Studies
  • Humans
  • Immediate Dental Implant Loading / methods*
  • Male
  • Middle Aged
  • Postoperative Complications
  • Surface Properties
  • Treatment Outcome
  • Young Adult
  • Zirconium / chemistry

Substances

  • Dental Materials
  • Zirconium
  • zirconium oxide