Dynamic contrast enhanced MRI monitoring of primary proton and carbon ion irradiation of prostate cancer using a novel hypofractionated raster scan technique

Radiother Oncol. 2016 Aug;120(2):313-9. doi: 10.1016/j.radonc.2016.05.012. Epub 2016 May 26.

Abstract

Purpose: To characterize parametric changes measured by sequential dynamic contrast enhanced perfusion MRI (DCE-MRI) during primary proton and carbon ion irradiation of prostate cancer using a novel hypofractionated raster scan technique to determine the potential of pharmacokinetic analysis for monitoring treatment effects of this novel irradiation scheme.

Materials and methods: Ninety-two patients were evaluated prospectively with DCE-MRI at baseline, day 10 during therapy, and 6weeks, 6months and 18months after treatment completion. After motion correction and co-registration to morphological T2-weighted images, tumors and normal appearing contralateral parenchyma (NACP) were segmented manually on T2W images and ROI statistics calculated for pharmacokinetic parameters K(trans), kep and ve using the standard Tofts model.

Results: The volume transfer constant (K(trans), p<0.001/p=0.010) and the leakage space partial volume (ve, p<0.001/p=0.005) showed a statistically significant increase during therapy with protons and carbon ions, respectively. Parametric increases occurred only in patients naive to antihormonal therapy (AHT), and were maximal 10days after the begining of treatment. The rate constant (kep) showed a significant increase only for proton, but not for carbon irradiation (p=0.021). Statistically significant differences between PC and NACP were observed for all parameters (p<0.001). AHT naïve patients with persistent PSA elevation above 1ng/ml at 12months experienced statistically significant elevation of K(trans) and ve compared to those with PSA suppression (p=0.04/p=0.023).

Conclusion: DCE parametric changes following ion particle irradiation of the prostate have not been previously reported. Their development into potential non-invasive imaging biomarkers for assessment of treatment response and efficacy is expected to be aided by the data on the magnitude and temporal evolution of parametric responses of cancer and normal tissue during and after therapy presented here, especially the changes of K(trans) and ve during therapy and their different measurement levels within tumors and in normal appearing contralateral tissue.

Keywords: Carbon ion irradiation; Dynamic contrast enhanced MRI; Particle irradiation; Prostate cancer; Proton irradiation; Radiation therapy.

Publication types

  • Clinical Trial, Phase II
  • Randomized Controlled Trial

MeSH terms

  • Aged
  • Carbon / therapeutic use
  • Contrast Media
  • Heavy Ion Radiotherapy / methods*
  • Humans
  • Image Enhancement / methods
  • Magnetic Resonance Imaging / methods
  • Male
  • Middle Aged
  • Models, Theoretical
  • Pilot Projects
  • Prostatic Neoplasms / diagnostic imaging*
  • Prostatic Neoplasms / pathology
  • Prostatic Neoplasms / radiotherapy*
  • Proton Therapy / methods*
  • Radionuclide Imaging / methods
  • Radiotherapy Planning, Computer-Assisted / methods

Substances

  • Contrast Media
  • Carbon