Functional Status Assessment of Patients With COPD: A Systematic Review of Performance-Based Measures and Patient-Reported Measures

Medicine (Baltimore). 2016 May;95(20):e3672. doi: 10.1097/MD.0000000000003672.

Abstract

Presently, there is no recommendation on how to assess functional status of chronic obstructive pulmonary disease (COPD) patients. This study aimed to summarize and systematically evaluate these measures.Studies on measures of COPD patients' functional status published before the end of January 2015 were included using a search filters in PubMed and Web of Science, screening reference lists of all included studies, and cross-checking against some relevant reviews. After title, abstract, and main text screening, the remaining was appraised using the Consensus-based Standards for the Selection of Health Measurement Instruments (COSMIN) 4-point checklist. All measures from these studies were rated according to best-evidence synthesis and the best-rated measures were selected.A total of 6447 records were found and 102 studies were reviewed, suggesting 44 performance-based measures and 14 patient-reported measures. The majority of the studies focused on internal consistency, reliability, and hypothesis testing, but only 21% of them employed good or excellent methodology. Their common weaknesses include lack of checks for unidimensionality, inadequate sample sizes, no prior hypotheses, and improper methods. On average, patient-reported measures perform better than performance-based measures. The best-rated patient-reported measures are functional performance inventory (FPI), functional performance inventory short form (FPI-SF), living with COPD questionnaire (LCOPD), COPD activity rating scale (CARS), University of Cincinnati dyspnea questionnaire (UCDQ), shortness of breath with daily activities (SOBDA), and short-form pulmonary functional status scale (PFSS-11), and the best-rated performance-based measures are exercise testing: 6-minute walk test (6MWT), endurance treadmill test, and usual 4-meter gait speed (usual 4MGS).Further research is needed to evaluate the reliability and validity of performance-based measures since present studies failed to provide convincing evidence. FPI, FPI-SF, LCOPD, CARS, UCDQ, SOBDA, PFSS-11, 6MWT, endurance treadmill test, and usual 4MGS performed well and are preferable to assess functional status of COPD patients.

Publication types

  • Review
  • Systematic Review

MeSH terms

  • Activities of Daily Living
  • Dyspnea / etiology
  • Humans
  • Psychometrics
  • Pulmonary Disease, Chronic Obstructive / complications
  • Pulmonary Disease, Chronic Obstructive / physiopathology*
  • Reproducibility of Results
  • Surveys and Questionnaires*
  • Walk Test*