Direct transfemoral transcatheter aortic valve implantation without balloon pre-dilatation using the Edwards Sapien XT valve

Catheter Cardiovasc Interv. 2016 Nov 15;88(6):978-985. doi: 10.1002/ccd.26564. Epub 2016 May 18.

Abstract

Objectives: To evaluate the feasibility and safety of direct transcatheter aortic valve implantation (TAVI) by the transfemoral approach without balloon pre-dilatation using the Edwards SapienXT valve.

Background: TAVI is established in selected high-risk patients with severe aortic stenosis. Balloon aortic valvuloplasty (BAV) is recommended prior to valve implantation, but may contribute to procedural risk. It is unknown whether this is necessary for successful passage and deployment of the device.

Methods: 81 patients (mean age 84 [95%CI:82-85.8], 62% male, median EuroScore 22.8% [95%CI:20.5-27]) undergoing transfemoral TAVI (35 by direct implantation [direct group]; 46 with balloon pre-dilatation [balloon group]) between 2010 and 2013 were analyzed for efficacy and safety endpoints.

Results: Procedural success was 100%. Pre and post-procedural peak gradients in the direct group were 66mmHg (95%CI:59-72.8) and 14mmHg (95%CI:12-17.8)(P < 0.0001) compared to 76.5mmHg (95%CI:73.7-94.0) and 17mmHg (95%CI:16-19)(P < 0.0001) in the balloon group. Post-dilatation was performed in 4/35(11.4%) of the direct group and 3/46(6.5%) of the balloon group (P = 0.83). Post procedure moderate AR was present in 1/35(2.9%) in the direct group and none in the balloon group. In-hospital mortality (2.9% direct vs. 0% balloon group), stroke (2.9% vs. 4.4%), tamponade (2.9% vs. 2.2%), major vascular complications (2.9% vs. 8.7%) and new permanent pacing (2.2% vs. 0) were similar. Pacing time, inflations, radiation dose and contrast use were all significantly lower in the direct group.

Conclusions: Direct implantation of the Edwards SapienXT valve during TAVI by the transfemoral route appears safe, efficacious and feasible in those without extreme calcification. © 2016 Wiley Periodicals, Inc.

Keywords: aortic stenosis; balloon aortic valvuloplasty; transcatheter aortic valve implantation.

MeSH terms

  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery*
  • Aortic Valve Stenosis / diagnosis
  • Aortic Valve Stenosis / surgery*
  • Balloon Valvuloplasty
  • Cardiac Catheterization / instrumentation*
  • Echocardiography
  • Female
  • Femoral Artery
  • Fluoroscopy
  • Heart Valve Prosthesis
  • Humans
  • Male
  • Prosthesis Design
  • Retrospective Studies
  • Severity of Illness Index
  • Transcatheter Aortic Valve Replacement / methods*
  • Treatment Outcome