Reducing absorbed dose to eye lenses in head CT examinations: the effect of bismuth shielding

Australas Phys Eng Sci Med. 2016 Jun;39(2):583-9. doi: 10.1007/s13246-016-0445-y. Epub 2016 Apr 20.

Abstract

The eye lens is considered to be among the most radiosensitive human tissues. Brain CT scans may unnecessarily expose it to radiation even if the area of clinical interest is far from the eyes. The aim of this study is to implement a bismuth eye lens shielding system for Head-CT acquisitions in these cases. The study is focused on the assessment of the dosimetric characteristics of the shielding system as well as on its effect on image quality. The shielding system was tested in two set-ups which differ for distance ("contact" and "4 cm" Set up respectively). Scans were performed on a CTDI phantom and an anthropomorphic phantom. A reference set up without shielding system was acquired to establish a baseline. Image quality was assessed by signal (not HU converted), noise and contrast-to-noise ratio (CNR) evaluation. The overall dose reduction was evaluated by measuring the CTDIvol while the eye lens dose reduction was assessed by placing thermoluminescent dosimeters (TLDs) on an anthropomorphic phantom. The image quality analysis exhibits the presence of an artefact that mildly increases the CT number up to 3 cm below the shielding system. Below the artefact, the difference of the Signal and the CNR are negligible between the three different set-ups. Regarding the CTDI, the analysis demonstrates a decrease by almost 12 % (in the "contact" set-up) and 9 % (in the "4 cm" set-up). TLD measurements exhibit an eye lens dose reduction by 28.5 ± 5 and 21.1 ± 5 % respectively at the "contact" and the "4 cm" distance. No relevant artefact was found and image quality was not affected by the shielding system. Significant dose reductions were measured. These features make the shielding set-up useful for clinical implementation in both studied positions.

Keywords: Bismuth shielding; Computed tomography; Dose reduction; Eye lens; Image quality.

MeSH terms

  • Absorption, Radiation*
  • Bismuth / chemistry*
  • Head
  • Humans
  • Lens, Crystalline / radiation effects*
  • Phantoms, Imaging
  • Radiation Protection*
  • Thermoluminescent Dosimetry
  • Tomography, X-Ray Computed

Substances

  • Bismuth