Sorption of structurally different ionized pharmaceutical and illicit drugs to a mixed-mode coated microsampler

J Chromatogr A. 2016 May 20:1447:1-8. doi: 10.1016/j.chroma.2016.04.017. Epub 2016 Apr 11.

Abstract

The mixed-mode (C18/strong cation exchange-SCX) solid-phase microextraction (SPME) fiber has recently been shown to have increased sensitivity for ionic compounds compared to more conventional sampler coatings such as polyacrylate and polydimethylsiloxane (PDMS). However, data for structurally diverse compounds to this (prototype) sampler coating are too limited to define its structural limitations. We determined C18/SCX fiber partitioning coefficients of nineteen cationic structures without hydrogen bonding capacity besides the charged group, stretching over a wide hydrophobicity range (including amphetamine, amitriptyline, promazine, chlorpromazine, triflupromazine, difenzoquat), and eight basic pharmaceutical and illicit drugs (pKa>8.86) with additional hydrogen bonding moieties (MDMA, atenolol, alprenolol, metoprolol, morphine, nicotine, tramadol, verapamil). In addition, sorption data for three neutral benzodiazepines (diazepam, temazepam, and oxazepam) and the anionic NSAID diclofenac were collected to determine the efficiency to sample non-basic drugs. All tested compounds showed nonlinear isotherms above 1mmol/L coating, and linear isotherms below 1mmol/L. The affinity for C18/SCX-SPME for tested organic cations without Hbond capacities increased with longer alkyl chains, ranging from logarithmic fiber-water distribution coefficients (log Dfw) of 1.8 (benzylamine) to 5.8 (triflupromazine). Amines smaller than benzylamine may thus have limited detection levels, while cationic surfactants with alkyl chain lengths >12 carbon atoms may sorb too strong to the C18/SCX sampler which hampers calibration of the fiber-water relationship in the linear range. The log Dfw for these simple cation structures closely correlates with the octanol-water partition coefficient of the neutral form (Kow,N), and decreases with increased branching and presence of multiple aromatic rings. Oxygen moieties in organic cations decreased the affinity for C18/SCX-SPME. Log Dfw values of neutral benzodiazepines were an order of magnitude higher than their log Kow,N. Results for anionic diclofenac species (logKow,N 4.5, pKa 4.0, log Dfw 2.9) indicate that the C18-SCX fiber might also be useful for sampling of organic anions. This data supports our theory that C18-based coatings are able to sorb ionized compounds through adsorption and demonstrates the applicability of C18-based SPME in the measurement of freely dissolved concentrations of a wide range of ionizable compounds.

Keywords: C18/SCX; Cation exchange; Cationic compounds; Mixed-mode fiber; Solid-phase microextraction.

MeSH terms

  • Adsorption
  • Alkanesulfonic Acids
  • Anions
  • Cations
  • Hydrophobic and Hydrophilic Interactions
  • Illicit Drugs / isolation & purification*
  • Ion Exchange Resins
  • Pharmaceutical Preparations / isolation & purification*
  • Silanes
  • Solid Phase Microextraction / instrumentation
  • Solid Phase Microextraction / methods
  • Water

Substances

  • Alkanesulfonic Acids
  • Anions
  • Cations
  • Illicit Drugs
  • Ion Exchange Resins
  • Pharmaceutical Preparations
  • Silanes
  • Water
  • propylsulfonic acid