Use of Contrast-Enhanced Ultrasonography to Evaluate Chronic Allograft Nephropathy in Rats and Correlations between Time-Intensity Curve Parameters and Allograft Fibrosis

Ultrasound Med Biol. 2016 Jul;42(7):1574-83. doi: 10.1016/j.ultrasmedbio.2016.01.028. Epub 2016 Apr 5.

Abstract

This study quantitatively analyzed changes in the hemodynamic characteristics of renal allografts at different stages in a rat chronic allograft nephropathy (CAN) model as well as the relationship between hemodynamic parameters and renal allograft fibrosis using contrast-enhanced ultrasonography (CEUS). The experimental group used a CAN rat model (n = 30), and the control group used an orthotopic syngeneic renal transplant model (n = 30). After surgery, creatinine clearance rates were regularly monitored every 2 wk. The checking times were set at 4, 12 and 24 wk after surgery, which represent early, middle and late stage of CAN, respectively. At different stages of CAN, eight rats from each group were randomly selected for CEUS examination. Time-intensity curve (TIC) parameters, including rise time, peak intensity, mean transit time, area under the curve, wash-in slope, time-to-peak and α-smooth muscle actin (α-SMA) expression; Vimentin expression; and chronic allograft damage index scores were evaluated by linear correlation analysis. Before the creatinine clearance rate showed significant abnormalities, the renal allografts in the experimental group had already presented pathologic changes associated with CAN. In the early stage after surgery, compared to the TIC curve of the control group, the experimental group showed increased rise time, mean transit time, area under the curve and time-to-peak, and decreased wash-in slope (p < 0.05). Chronic allograft damage index scores and the expression levels of α-SMA and Vimentin proteins in renal allografts were correlated with TIC parameters (p < 0.05). Compared to creatinine clearance rate, CEUS can detect CAN at earlier stages. The correlations between TIC-related parameters and the expression levels of α-SMA and Vimentin in renal allografts indicate that CEUS is a feasible way to assess the degree of renal allograft fibrosis quantitatively.

Keywords: Allograft fibrosis; Chronic allograft nephropathy; Contrast-enhanced ultrasonography; Time-intensity curve.

MeSH terms

  • Allografts
  • Animals
  • Contrast Media*
  • Disease Models, Animal
  • Fibrosis
  • Image Enhancement / methods*
  • Kidney / diagnostic imaging
  • Kidney / pathology
  • Kidney / surgery
  • Kidney Diseases / diagnostic imaging*
  • Kidney Diseases / pathology
  • Kidney Transplantation*
  • Male
  • Postoperative Complications / diagnostic imaging*
  • Postoperative Complications / pathology
  • Rats
  • Rats, Inbred F344
  • Ultrasonography / methods*

Substances

  • Contrast Media