Data on comparison between FLEC and CLIMPAQ methods used for fast sorption measurements of VOCs on building materials

Data Brief. 2016 Mar 7:7:518-23. doi: 10.1016/j.dib.2016.02.072. eCollection 2016 Jun.

Abstract

A test emission chamber called CLIMPAQ has been coupled to a chromatography analyzer GC to measure volatile organic compounds (VOC) concentration during a sorption experiments (Fast sorption measurements of VOCs on building materials: Part 2 - Comparison between FLEC and CLIMPAQ methods, (Rizk et al., In press) [1]). The equations used to calculate the mass transfer coefficient and the thickness of the boundary layer developed on the surface of a material are presented. In addition, the experimental profiles obtained using the CLIMPAQ chamber is also presented in the presence and the absence of a building material. Finally, the impact of chamber size on the obtained concentration profile using different chambers is shown using 3 types of chambers having different volumes, 1 m(3), 30 m(3) and a micro chamber of 40 mL.