Radiotherapy dose enhancement using BNCT in conventional LINACs high-energy treatment: Simulation and experiment

Rep Pract Oncol Radiother. 2016 Mar-Apr;21(2):117-22. doi: 10.1016/j.rpor.2015.07.003. Epub 2015 Aug 10.

Abstract

Aim: To employ the thermal neutron background that affects the patient during a traditional high-energy radiotherapy treatment for BNCT (Boron Neutron Capture Therapy) in order to enhance radiotherapy effectiveness.

Background: Conventional high-energy (15-25 MV) linear accelerators (LINACs) for radiotherapy produce fast secondary neutrons in the gantry with a mean energy of about 1 MeV due to (γ, n) reaction. This neutron flux, isotropically distributed, is considered as an unavoidable undesired dose during the treatment. Considering the moderating effect of human body, a thermal neutron fluence is localized in the tumour area: this neutron background could be employed for BNCT by previously administering (10)B-Phenyl-Alanine ((10)BPA) to the patient.

Materials and methods: Monte Carlo simulations (MCNP4B-GN code) were performed to estimate the total amount of neutrons outside and inside human body during a traditional X-ray radiotherapy treatment. Moreover, a simplified tissue equivalent anthropomorphic phantom was used together with bubble detectors for thermal and fast neutron to evaluate the moderation effect of human body.

Results: Simulation and experimental results confirm the thermal neutron background during radiotherapy of 1.55E07 cm(-2) Gy(-1). The BNCT equivalent dose delivered at 4 cm depth in phantom is 1.5 mGy-eq/Gy, that is about 3 Gy-eq (4% of X-rays dose) for a 70 Gy IMRT treatment.

Conclusions: The thermal neutron component during a traditional high-energy radiotherapy treatment could produce a localized BNCT effect, with a localized therapeutic dose enhancement, corresponding to 4% or more of photon dose, following tumour characteristics. This BNCT additional dose could thus improve radiotherapy, acting as a localized radio-sensitizer.

Keywords: BNCT; Neutron; Photo-production; e-LINAC.