Method for analysis of psychopharmaceuticals in real industrial wastewater and groundwater with suspended organic particulate matter using solid phase extraction disks extraction and ultra-high performance liquid chromatography/time-of-flight mass spectrometry

J Chromatogr A. 2016 Apr 1:1440:15-22. doi: 10.1016/j.chroma.2016.02.035. Epub 2016 Feb 12.

Abstract

A rapid and reliable analytical method was developed for the quantitative determination of psychopharmaceuticals, their precursors and by-products in real contaminated samples from a pharmaceutical company in Olomouc (Czech Republic), based on SPE disk extraction and detection by ultra performance liquid chromatography, combined with time-of-flight mass spectrometry. The target compounds were quantified in the real whole-water samples (water including suspended particles), both in the presence of suspended particulate matter (SPM) and high concentrations of other organic pollutants. A total of nine compounds were analyzed which consisted of three commonly used antidepressants (tricyclic antidepressants and antipsychotics), one antitussive agent and five by-products or precursors. At first, the SPE disk method was developed for the extraction of water samples (dissolved analytes, recovery 84-104%) and pressurised liquid extraction technique was verified for solid matrices (sludge samples, recovery 81-95%). In order to evaluate the SPE disk technique for whole water samples containing SPM, non contaminated groundwater samples were also loaded with different amounts (100 and 300mgL(-1)) of real contaminated sludge originating from the same locality. The recoveries from the whole-water samples obtained by SPE disk method ranged between 67 and 119% after the addition of the most contaminated sludge. The final method was applied to several real groundwater (whole-water) samples from the industrial area and high concentrations (up to 10(3)μgL(-1)) of the target compounds were detected. The results of this study document and indicate the feasibility of the SPE disk method for analysis of groundwater.

Keywords: Groundwater; Pharmaceuticals; SPE disks; Sludge; Suspended particulate matter; Whole-water.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Chromatography, High Pressure Liquid
  • Czech Republic
  • Environmental Monitoring / instrumentation
  • Environmental Monitoring / methods*
  • Groundwater / chemistry*
  • Mass Spectrometry*
  • Particulate Matter / analysis*
  • Psychotropic Drugs / analysis*
  • Solid Phase Extraction*
  • Wastewater / chemistry*
  • Water Pollutants, Chemical / analysis

Substances

  • Particulate Matter
  • Psychotropic Drugs
  • Waste Water
  • Water Pollutants, Chemical