Solid-phase extraction in combination with dispersive liquid-liquid microextraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis: the ultra-trace determination of 10 antibiotics in water samples

Anal Bioanal Chem. 2016 Feb;408(6):1701-13. doi: 10.1007/s00216-015-9284-z. Epub 2016 Jan 15.

Abstract

A novel method, solid-phase extraction combined with dispersive liquid-liquid microextraction (SPE-DLLME), was developed for ultra-preconcentration of 10 antibiotics in different environmental water samples prior to ultra-high performance liquid chromatography-tandem mass spectrometry detection. The optimized results were obtained as follows: after being adjusted to pH 4.0, the water sample was firstly passed through PEP-2 column at 10 mL min(-1), and then methanol was used to elute the target analytes for the following steps. Dichloromethane was selected as extraction solvent, and methanol/acetonitrile (1:1, v/v) as dispersive solvent. Under optimal conditions, the calibration curves were linear in the range of 1-1000 ng mL(-1) (sulfamethoxazole, cefuroxime axetil), 5-1000 ng mL(-1) (tinidazole), 10-1000 ng mL(-1) (chloramphenicol), 2-1000 ng mL(-1) (levofloxacin oxytetracycline, doxycycline, tetracycline, and ciprofloxacin) and 1-400 ng mL(-1) (sulfadiazine) with a good precision. The LOD and LOQ of the method were at very low levels, below 1.67 and 5.57 ng mL(-1), respectively. The relative recoveries of the target analytes were in the range from 64.16% to 99.80% with relative standard deviations between 0.7 and 8.4%. The matrix effect of this method showed a great decrease compared with solid-phase extraction and a significant value of enrichment factor (EF) compared with dispersive liquid-liquid microextraction. The developed method was successfully applied to the extraction and analysis of antibiotics in different water samples with satisfactory results.

Keywords: Antibiotics; Dispersive liquid-liquid microextraction; Solid-phase extraction; Ultra-high performance liquid chromatography-tandem mass spectrometry; Water samples.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acetonitriles
  • Anti-Bacterial Agents / analysis*
  • Calibration
  • Chromatography, High Pressure Liquid / methods*
  • Drinking Water / analysis
  • Hydrogen-Ion Concentration
  • Limit of Detection
  • Liquid Phase Microextraction / methods*
  • Methanol / chemistry
  • Rivers / chemistry
  • Solid Phase Extraction / methods*
  • Solvents / chemistry
  • Tandem Mass Spectrometry / methods*
  • Wastewater / analysis
  • Water Pollutants, Chemical / analysis*

Substances

  • Acetonitriles
  • Anti-Bacterial Agents
  • Drinking Water
  • Solvents
  • Waste Water
  • Water Pollutants, Chemical
  • Methanol
  • acetonitrile