High-intensity static magnetic field exposure devices for in vitro experiments on biopharmaceutical plant factories in aerospace environments

Annu Int Conf IEEE Eng Med Biol Soc. 2015 Aug:2015:893-6. doi: 10.1109/EMBC.2015.7318506.

Abstract

Three high-intensity static magnetic field (SMF) exposure devices have been designed and realized for application to in vitro experimental research on hairy root cultures, supposed to grow in extreme environments- as those of space aircrafts- for producing biopharmaceutical molecules. The devices allow the exposure at two different levels of induction magnetic (B) field (250 mT and 500 mT) plus sham for blind exposure. The exposure levels can be considered representative of possible B-fields experienced within the habitat of a spacecraft in presence of active magnetic shielding systems. Each device can house a single 85-mm diameter Petri dish. Numerical simulations have been performed to accurately evaluate the B-field distribution in the biological target. Numerical results have been confirmed by measured data, proving that designed setups allows exposure to SMFs with a homogeneity better than 90%. The exposure devices will be employed for experiments scheduled within BIOxTREME research project, funded by the Italian Space Agency (ASI).

MeSH terms

  • Astronomical Phenomena
  • Magnetic Fields*
  • Magnetics