Signal decay mapping of myocardial edema using dual-contrast fast spin-echo MRI

J Magn Reson Imaging. 2016 Jul;44(1):186-93. doi: 10.1002/jmri.25142. Epub 2015 Dec 31.

Abstract

Purpose: To introduce a dual-contrast fast spin-echo (dcFSE) sequence for signal decay mapping of myocardial edema.

Materials and methods: After consultation with the Institutional Review Board, 22 acute myocardial infarction (MI) patients were examined with magnetic resonance imaging (MRI) at 1.5T 2 days after revascularization. Edema was evaluated in 16 myocardial segments with an exponential fit for signal decay time (SDT) in dcFSE mapping and T2 signal intensity ratio for single-contrast FSE. Myocardial viability was evaluated in late gadolinium enhancement (LGE). A control group of 10 volunteers was examined for edema imaging. SDT was compared in segment groups: 1) with LGE in MI, 2) penumbra, 3) remote from LGE, 4) controls. Groups 1/3 and 3/4 were tested on difference. Three phantoms providing similar T2 but different T1 relaxation times (low, intermediate, high) were examined with dcFSE and multicontrast spin echo sequence as a reference.

Results: The SDT/T2 ratio for segment groups was 1) 82msec/1.7 in segments with LGE; 2) 65msec/1.6 for penumbra, 3) 62msec/1.7 for remote segments, and 4) 50msec/1.6 in controls. In dcFSE group 1/3 (P < 0.0001) and in group 3/4 (P = 0.0002) SDT was significantly different. In single-contrast FSE the T2 ratio was not significantly different for both tests: 1/3 P = 0.1889; 3/4 P = 0.8879. T2 -overestimation of dcFSE was 23% in low, 29% in intermediate, and 35% in highly T1 contaminated phantoms.

Conclusion: dcFSE signal decay edema mapping is feasible in volunteers and patients. DcFSE SDT is superior to T2 ratio for detection of high-grade and diffuse myocardial edema. J. Magn. Reson. Imaging 2016;44:186-193.

Keywords: FSE; T2 mapping; cardiac MRI; edema; fast-spin-echo.

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Algorithms*
  • Cardiac Imaging Techniques / methods*
  • Contrast Media / administration & dosage
  • Edema, Cardiac / diagnostic imaging*
  • Female
  • Humans
  • Image Enhancement / methods
  • Image Interpretation, Computer-Assisted / methods*
  • Magnetic Resonance Imaging, Cine / methods*
  • Male
  • Middle Aged
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Spin Labels

Substances

  • Contrast Media
  • Spin Labels