Complication from combined use of capsule retractors and capsular tension rings in zonular dehiscence

J Cataract Refract Surg. 2015 Nov;41(11):2576-9. doi: 10.1016/j.jcrs.2015.10.012.

Abstract

We describe a new complication associated with capsular tension ring (CTR) implantation after placement of capsule retractors. We report 3 cases from 3 different surgeons of inadvertent threading of a CTR through a capsule retractor loop. In each case, the distal loop was opened or amputated to facilitate hook removal. We report this case series to alert cataract surgeons to a potential complication of using CTRs and capsule retractors together and to offer potential strategies for preventing and managing an intracapsular entanglement.

Financial disclosure: Dr. Kim is a consultant to Alcon Surgical, Inc. Dr. Chang receives personal fees from Abbott Medical Optics, Inc. Dr. Condon receives personal fees from Alcon Surgical, Inc. and Microsurgical Technology. No other author has a financial or proprietary interest in any material or method mentioned.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Aged
  • Cataract / complications
  • Female
  • Humans
  • Intraoperative Complications*
  • Lens Capsule, Crystalline / surgery*
  • Lens Implantation, Intraocular
  • Ligaments / pathology*
  • Middle Aged
  • Phacoemulsification / adverse effects*
  • Phacoemulsification / instrumentation
  • Prostheses and Implants / adverse effects*