In-line ATR-UV and Raman Spectroscopy for Monitoring API Dissolution Process During Liquid-Filled Soft-Gelatin Capsule Manufacturing

AAPS PharmSciTech. 2016 Oct;17(5):1173-81. doi: 10.1208/s12249-015-0456-0. Epub 2015 Nov 24.

Abstract

Complete dissolution of the active pharmaceutical ingredient (API) is critical in the manufacturing of liquid-filled soft-gelatin capsules (SGC). Attenuated total reflectance UV spectroscopy (ATR-UV) and Raman spectroscopy have been investigated for in-line monitoring of API dissolution during manufacturing of an SGC product. Calibration models have been developed with both techniques for in-line determination of API potency. Performance of both techniques was evaluated and compared. The ATR-UV methodology was found to be able to monitor the dissolution process and determine the endpoint, but was sensitive to temperature variations. The Raman technique was also capable of effectively monitoring the process and was more robust to the temperature variation and process perturbations by using an excipient peak for internal correction. Different data preprocessing methodologies were explored in an attempt to improve method performance.

Keywords: ATR-UV; Raman; in-line monitoring; soft-gelatin capsule.

MeSH terms

  • Calibration
  • Capsules / chemistry*
  • Chemistry, Pharmaceutical / methods
  • Excipients / chemistry
  • Gelatin / chemistry*
  • Pharmaceutical Preparations / chemistry*
  • Solubility
  • Spectrum Analysis, Raman / methods
  • Technology, Pharmaceutical / methods*
  • Temperature
  • Ultraviolet Rays

Substances

  • Capsules
  • Excipients
  • Pharmaceutical Preparations
  • Gelatin