Far field 3D localization of radioactive hot spots using a coded aperture camera

Appl Radiat Isot. 2016 Jan:107:177-182. doi: 10.1016/j.apradiso.2015.10.021. Epub 2015 Oct 20.

Abstract

This paper presents a coded aperture method to remotely estimate the radioactivity of a source. The activity is estimated from the detected counts and the estimated source location, which is extracted by factoring the effect of aperture magnification. A 6mm thick tungsten-copper alloy coded aperture mask is used to modulate the incoming gamma-rays. The location of point and line sources in all three dimensions was estimated with an accuracy of less than 10% when the source-camera distance was about 4 m. The estimated activities were 17.6% smaller and 50.4% larger than the actual activities for the point and line sources, respectively.

Keywords: Coded aperture; Far-filed measurements; Gamma camera; Modified Uniformly Redundant Array (MURA); Source activity determination; Source localization.