Robot-assisted laparoscopic total extraperitoneal hernia repair during prostatectomy: technique and initial experience

Cent European J Urol. 2015;68(2):240-4. doi: 10.5173/ceju.2015.562. Epub 2015 Jun 18.

Abstract

Introduction: To describe the technique of total extraperitoneal inguinal hernia repair performed during Robot-assisted Endoscopic Extraperitoneal Radical Prostatectomy (R-EERPE) and to present the initial outcomes.

Material and methods: 12 patients underwent inguinal hernia repair during 120 R-EERPEs performed between July 2011 and March 2012. All patients had a clinically palpable inguinal hernia preoperatively. The hernia was repaired using a Total Extraperitoneal Patch (TEP) at the end of the procedure.

Results: Sac dissection and mesh placement was simpler compared to conventional laparoscopy due to improved, magnified, 3-D vision along with 7° of movement, and better control of mesh placement. The median operating time was 185 minutes, with on average, an additional 12 minutes incurred per hernia repair. The median blood loss for the procedures was 250 ml, and the mean pathological prostate weight was 55 gm. No additional blood loss was noted and there were no postoperative complications. None of the patients had a recurrence at 12 months. We await long-term follow-up data.

Conclusions: Robot-assisted TEP is feasible and should be considered in patients with hernia at the time of R-EERPE.

Keywords: extraperitoneal; hernia; mesh; prostatectomy; robot assisted.