Differential diagnosis of benign and malignant breast masses using diffusion-weighted magnetic resonance imaging

World J Surg Oncol. 2015 Feb 7:13:32. doi: 10.1186/s12957-014-0431-3.

Abstract

Background: Diffusion-weighted magnetic resonance imaging (DW-MRI) is different from conventional diagnostic methods and has the potential to delineate the microscopic anatomy of a target tissue or organ. The purpose of our study was to evaluate the value of DW-MRI in the diagnosis of benign and malignant breast masses, which would help the clinical surgeon to decide the scope and pattern of operation.

Methods: A total of 52 female patients with palpable solid breast masses received breast MRI scans using routine sequences, dynamic contrast-enhanced imaging, and diffusion-weighted echo-planar imaging at b values of 400, 600, and 800 s/mm(2), respectively. Two regions of interest (ROIs) were plotted, with a smaller ROI for the highest signal and a larger ROI for the overall lesion. Apparent diffusion coefficient (ADC) values were calculated at three different b values for all detectable lesions and from two different ROIs. The sensitivity, specificity, positive predictive value, and positive likelihood ratio of DW-MRI were determined for comparison with histological results.

Results: A total of 49 (49/52, 94.2%) lesions were detected using DW-MRI, including 20 benign lesions (two lesions detected in the same patient) and 29 malignant lesions. Benign lesion had a higher mean ADC value than their malignant counterparts, regardless of b value. According to the receiver operating characteristic (ROC) curve, the smaller-range ROI was more effective in differentiation between benign and malignant lesions. The area under the ROC curve was the largest at a b value of 800 s/mm(2). With a threshold ADC value at 1.23 × 10(-3) mm(2)/s, DW-MRI achieved a sensitivity of 82.8%, specificity of 90.0%, positive predictive value of 92.3%, and positive likelihood ratio of 8.3 for differentiating benign and malignant lesions.

Conclusions: DW-MRI is an accurate diagnostic tool for differentiation between benign and malignant breast lesions, with an optimal b value of 800 s/mm(2). A smaller-range ROI focusing on the highest signal has a better differential value.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Breast / pathology*
  • Breast Neoplasms / diagnosis*
  • Carcinoma, Ductal, Breast / diagnosis*
  • Carcinoma, Lobular / diagnosis*
  • Diagnosis, Differential
  • Diffusion Magnetic Resonance Imaging / methods*
  • Female
  • Follow-Up Studies
  • Humans
  • Image Enhancement
  • Image Interpretation, Computer-Assisted / methods
  • Magnetic Resonance Imaging
  • Middle Aged
  • Neoplasm Invasiveness
  • Neoplasm Staging
  • Prognosis
  • ROC Curve
  • Retrospective Studies
  • Young Adult