Microscale Sensing of Oxygen via Encapsulated Porphyrin Nanofibers: Effect of Indicator and Polymer "Core" Permeability

ACS Appl Mater Interfaces. 2015 Apr 29;7(16):8606-14. doi: 10.1021/acsami.5b00403. Epub 2015 Apr 16.

Abstract

Biomimetic polymer nanofibers integrate sensing capabilities creating utility across many biological and biomedical applications. We created fibers consisting of either a poly(ether sulfone) (PES) or a polysulfone (PSU) core coated by a biocompatible polycaprolactone (PCL) shell to facilitate cell attachment. Oxygen sensitive luminescent probes Pt(II) meso-tetra(pentafluorophenyl)porphine (PtTFPP) or Pd(II) meso-tetra(pentafluorophenyl)porphine (PdTFPP), were incorporated in the core via single-step coaxial electrospinning providing superior sensitivity, high brightness, linear response, and excellent stability. Both PES-PCL and PSU-PCL fibers provide more uniform probe distribution than polydimethylsiloxane (PDMS). PSU-based sensing fibers possessed optimum sensitivity due to their relatively higher oxygen permeability. During exposure to 100% nitrogen and 100% oxygen, PES-PCL fiber displayed an I0/I100 value of 6.7; PSU-PCL exhibited a value of 8.9 with PtTFPP as the indicator. In contrast, PdTFPP-containing fibers possess higher sensitivity due to the long porphyrin lifetime. The corresponding I0/I100 values were 80.6 and 106.7 for the PES-PCL and PSU-PCL matrices, respectively. The response and recovery times were 0.24/0.39 s for PES-PCL and 0.38/0.83 s for PSU-PCL which are 0.12 and 0.11 s faster, respectively, than the Pt-based porphyrin in the same matrices. Paradoxically, lower oxygen permeabilities make these polymers better suited to measuring higher (i. e., ∼20%) oxygen contents than PDMS. Individual fiber sensing was studied by fluorescence spectrometry and at a sub-micrometer scale by total internal reflection fluorescence (TIRF). Specific polymer blends relate polymer composition to the resulting sensor properties. All compositions displayed linear Stern-Volmer plots; sensitivity could be tailored by matrix or the sensing probe selection.

Keywords: electrospinning; hypoxia; luminescence; oxygen sensor; permeability; polyacrylonitrile.

Publication types

  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Acrylic Resins / chemistry
  • Cell Line, Tumor
  • Humans
  • Image Processing, Computer-Assisted
  • Nanofibers / chemistry*
  • Nanofibers / ultrastructure
  • Nitrogen / analysis
  • Oxygen / analysis*
  • Permeability
  • Polyesters
  • Polymers / chemistry*
  • Porphyrins / chemistry*
  • Spectrometry, Fluorescence
  • Sulfones / chemistry

Substances

  • Acrylic Resins
  • Polyesters
  • Polymers
  • Porphyrins
  • Sulfones
  • polycaprolactone
  • polyacrylonitrile
  • polysulfone P 1700
  • polyether sulfone
  • Nitrogen
  • Oxygen