Quantitative determination of lercanidipine enantiomers in commercial formulations by capillary electrophoresis

J Anal Methods Chem. 2015:2015:294270. doi: 10.1155/2015/294270. Epub 2015 Mar 2.

Abstract

An enantioselective method based on capillary electrophoresis (CE) using cyclodextrin (CD) as chiral selector was developed and validated for determination of lercanidipine (LER) enantiomers, a drug calcium channel blocker which exerts antihypertensive effects of long duration, in a pharmaceutical formulation. Optimum separation of LER enantiomers was obtained on a 50 cm × 50 μm id capillary using a sodium acetate buffer solution 200 mmol/L pH 4.0 containing 10 mmol/L of 2,3,6-o-methyl-β-cyclodextrin (TM-β-CD) as background electrolyte. The capillary temperature and voltage were 15°C and 25 kV, respectively, hydrodynamic injection and detection at 237 nm. Linearity was obtained in the range 12.5-100 μg/mL for both enantiomers (r ≥ 0.995). The RSD (%) and relative errors (E, %) obtained in precision and accuracy studies (intraday and interday) were lower than 5%. After validation, the method was applied to quantify the enantiomers of LER in commercial tablets and the results were satisfactory in terms of accuracy and precision, both less than 5%. Therefore, this method was found to be appropriate for enantioselective quality control of LER enantiomers in pharmaceutical formulations.