CT angiography of neonates and infants: comparison of radiation dose and image quality of target mode prospectively ECG-gated 320-MDCT and ungated helical 64-MDCT

AJR Am J Roentgenol. 2015 Feb;204(2):W184-91. doi: 10.2214/AJR.14.12846.

Abstract

OBJECTIVE. The purpose of this study was to evaluate the radiation dose and image quality of target mode prospectively ECG-gated volumetric CT angiography (CTA) performed with a 320-MDCT scanner compared with the radiation dose and image quality of ungated helical CTA performed with a 64-MDCT scanner. MATERIALS AND METHODS. An experience with CTA for cardiovascular indications in neonates and infants 0-6 months old was retrospectively assessed. Radiation doses and quantitative and qualitative image quality scores of 28 CTA examinations performed with a 320-MDCT scanner and volumetric target mode prospective ECG gating plus iterative reconstruction (target mode) were compared with the doses and scores of 28 CTA examinations performed with a 64-MDCT scanner and ungated helical scanning plus filtered back projection reconstruction (ungated mode). All target mode studies were performed during free breathing. Seven ungated CTA examinations (25%) were performed with general endotracheal anesthesia. The findings of 17 preoperative CTA examinations performed in target mode were also compared with surgical reports for evaluation of diagnostic accuracy. RESULTS. All studies performed with target mode technique were diagnostic for the main clinical indication. Effective doses were significantly lower in the target mode group (0.51 ± 0.19 mSv) compared with the ungated mode group (4.8 ± 1.4 mSv) (p < 0.0001). Quantitative analysis revealed no statistically significant difference between the two groups with respect to signal-to-noise ratio (of pulmonary artery and aorta) and contrast-to-noise ratio. Subjective image quality was significantly better with target mode than with ungated mode (p < 0.0001). CONCLUSION. Target mode prospectively ECG-gated volumetric scanning with iterative reconstruction performed with a 320-MDCT scanner has several benefits in cardiovascular imaging of neonates and infants, including low radiation dose, improved image quality, high diagnostic accuracy, and ability to perform free-breathing studies.

Keywords: CT angiography; congenital heart disease; neonates and infants; prospective ECG gating; radiation dose; target mode; volumetric scanning.

Publication types

  • Comparative Study
  • Evaluation Study

MeSH terms

  • Cardiac-Gated Imaging Techniques* / methods
  • Coronary Angiography / methods*
  • Electrocardiography
  • Female
  • Humans
  • Infant
  • Infant, Newborn
  • Male
  • Multidetector Computed Tomography / methods*
  • Radiation Dosage*
  • Retrospective Studies
  • Tomography, Spiral Computed*
  • Tomography, X-Ray Computed