Detection of response to command using voluntary control of breathing in disorders of consciousness

Front Hum Neurosci. 2014 Dec 23:8:1020. doi: 10.3389/fnhum.2014.01020. eCollection 2014.

Abstract

Background: Detecting signs of consciousness in patients in a vegetative state/unresponsive wakefulness syndrome (UWS/VS) or minimally conscious state (MCS) is known to be very challenging. Plotkin et al. (2010) recently showed the possibility of using a breathing-controlled communication device in patients with locked in syndrome. We here aim to test a breathing-based "sniff controller" that could be used as an alternative diagnostic tool to evaluate response to command in severely brain damaged patients with chronic disorders of consciousness (DOC).

Methods: Twenty-five DOC patients were included. Patients' resting breathing-amplitude was measured during a 5 min resting condition. Next, they were instructed to end the presentation of a music sequence by sniffing vigorously. An automated detection of changes in breathing amplitude (i.e., >1.5 SD of resting) ended the music and hence provided positive feedback to the patient.

Results: None of the 11 UWS/VS patients showed a sniff-based response to command. One out of 14 patients with MCS was able to willfully modulate his breathing pattern to answer the command on 16/19 trials (accuracy 84%). Interestingly, this patient failed to show any other motor response to command.

Discussion: We here illustrate the possible interest of using breathing-dependent response to command in the detection of residual cognition in patients with DOC after severe brain injury.

Keywords: brain-computer interface; breathing; diagnosis; disorders of consciousness; minimally conscious state; sniffing; unresponsive wakefulness syndrome; vegetative state.