High resolution/accurate mass (HRMS) detection of anatoxin-a in lake water using LDTD-APCI coupled to a Q-Exactive mass spectrometer

Talanta. 2015 Jan:132:836-44. doi: 10.1016/j.talanta.2014.10.021. Epub 2014 Oct 31.

Abstract

A new innovative analytical method combining ultra-fast analysis time with high resolution/accurate mass detection was developed to eliminate the misidentification of anatoxin-a (ANA-a), a cyanobacterial toxin, from the natural amino acid phenylalanine (PHE). This was achieved by using the laser diode thermal desorption-atmospheric pressure chemical ionization (LDTD-APCI) coupled to the Q-Exactive, a high resolution/accurate mass spectrometer (HRMS). This novel combination, the LDTD-APCI-HRMS, allowed for an ultra-fast analysis time (<15 s/sample). A comparison of two different acquisition modes (full scan and targeted ion fragmentation) was made to determine the most rigorous analytical method using the LDTD-APCI interface. Method development focused toward selectivity and sensitivity improvement to reduce the possibility of false positives and to lower detection limits. The Q-Exactive mass spectrometer operates with resolving powers between 17500 and 140000 FWHM (m/z 200). Nevertheless, a resolution of 17500FWHM is enough to dissociate ANA-a and PHE signals. Mass accuracy was satisfactory with values below 1 ppm reaching precision to the fourth decimal. Internal calibration with standard addition was achieved with the isotopically-labeled (D5) phenylalanine with good linearity (R(2)>0.999). Enhancement of signal to noise ratios relative to a standard triple-quadrupole method was demonstrated with lower detection and quantification limit values of 0.2 and 0.6 μg/L using the Q-Exactive. Accuracy and interday/intraday relative standard deviations were below 15%. The new method was applied to 8 different lake water samples with signs of cyanobacterial blooms. This work demonstrates the possibility of using an ultra-fast LDTD-APCI sample introduction system with an HRMS hybrid instrument for quantitative purposes with high selectivity in complex environmental matrices.

Keywords: Anatoxin-a; Cyanobacteria; High resolution mass spectrometry; LDTD–APCI; Phenylalanine.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Anabaena / chemistry
  • Calibration
  • Cyanobacteria Toxins
  • Harmful Algal Bloom
  • Lakes
  • Limit of Detection
  • Mass Spectrometry / instrumentation
  • Mass Spectrometry / methods*
  • Observer Variation
  • Phenylalanine / analysis
  • Reference Standards
  • Time Factors
  • Tropanes / analysis*
  • Water Pollutants, Chemical / analysis*

Substances

  • Cyanobacteria Toxins
  • Tropanes
  • Water Pollutants, Chemical
  • Phenylalanine
  • anatoxin a