A new technique for retaining double crowns on implants via custom-positioned vertical screws

Int J Prosthodont. 2014 Nov-Dec;27(6):577-8. doi: 10.11607/ijp.3882.

Abstract

This report describes the use of custom-positioned vertical screws (CVS) to attach primary telescopic crowns to implant abutments. In a private practice setting, 37 patients with 40 double crown-retained implant overdentures (IODs) with a clearance fit (Marburg double crowns) were followed. All primary crowns on the 120 implant abutments were retained using CVS. After a mean followup period of 3.55 ± 1.37 years (range: 1.5 to 6.3 years), one abutment screwloosening incident was reported (incidence: 0.08%). No loosening of any of the screw-retained primary crowns occurred. CVS may represent a viable fixation concept for IODs.

MeSH terms

  • Aged
  • Crowns*
  • Dental Implant-Abutment Design
  • Dental Implants, Single-Tooth
  • Dental Prosthesis Retention / instrumentation*
  • Dental Prosthesis Retention / methods
  • Dental Prosthesis, Implant-Supported*
  • Dental Restoration Failure
  • Denture, Overlay
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Retrospective Studies
  • Survival Analysis
  • Treatment Outcome