Biomechanical study of the funnel technique applied in thoracic pedicle screw replacement

Afr Health Sci. 2014 Sep;14(3):716-24. doi: 10.4314/ahs.v14i3.30.

Abstract

Background: Funnel technique is a method used for the insertion of screw into thoracic pedicle.

Aim: To evaluate the biomechanical characteristics of thoracic pedicle screw placement using the Funnel technique, trying to provide biomechanical basis for clinical application of this technology.

Methods: 14 functional spinal units (T6 to T10) were selected from thoracic spine specimens of 14 fresh adult cadavers, and randomly divided into two groups, including Funnel technique group (n = 7) and Magerl technique group (n = 7). The displacement-stiffness and pull-out strength in all kinds of position were tested and compared.

Results: Two fixed groups were significantly higher than that of the intact state (P < 0.05) in the spinal central axial direction, compression, anterior flexion, posterior bending, lateral bending, axial torsion, but there were no significant differences between two fixed groups (P > 0.05). The mean pull-out strength in Funnel technique group (789.09 ± 27.33) was lower than that in Magerl technique group (P < 0.05).

Conclusions: The Funnel technique for the insertion point of posterior bone is a safe and accurate technique for pedicle screw placement. It exhibited no effects on the stiffness of spinal column, but decreased the pull-out strength of pedicle screw. Therefore, the funnel technique in the thoracic spine affords an alternative for the standard screw placement.

Keywords: Biomechanics; Funnel technique; Pedicle screws; Thoracic.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Adult
  • Biomechanical Phenomena
  • Bone Screws*
  • Cadaver
  • Female
  • Humans
  • Male
  • Middle Aged
  • Orthopedic Procedures / methods*
  • Radiography
  • Spinal Diseases / surgery*
  • Thoracic Vertebrae / diagnostic imaging
  • Thoracic Vertebrae / surgery*