A comparison of sperm RNA-seq methods

Syst Biol Reprod Med. 2014 Oct;60(5):308-15. doi: 10.3109/19396368.2014.944318. Epub 2014 Jul 31.

Abstract

A significant challenge to the effective application of RNA-seq to the complete transcript analysis of low quantity and/or degraded samples is the amplification of minimal input RNA to enable sequencing library construction. Several strategies have been commercialized in order to facilitate this goal. However, each strategy has its own specific protocols and methodology, and each may introduce unique bias and in some cases show specific preference for a collection of sequences. Our wider investigation of human spermatozoal RNAs was able to reveal their complexity despite being generally characterized by low quantity and high fragmentation. In this study, the following four commercially available RNA-seq amplification and library protocols for the preparation of low quantity/highly fragmented samples, SMARTer™ Ultra Low RNA (SU) for Illumina® Sequencing, SeqPlex RNA Amplification (SP), Ovation® RNA-Seq System V2 (OR), and Ovation® RNA-Seq Formalin Fixed Paraffin Embedded System (FFPES) were assessed using human sperm RNAs. Further investigation analyzed the effects on the end results of two different library preparation methods, Encore NGS Multiplex System I (Enc) and Ovation Ultralow Library Systems (UL), that appeared best suited to this type of RNA, along with other potential confounding factors such as FFPE preservation. Our results indicate that for each library preparation protocol, the differences in the initial amount of input RNA and choice of RNA purification step do not generate marked differences in terms of RNA profiling. However, substantial disparity is introduced by individual amplification methods prior to library construction. These significant differences may be caused by the different priming methods or amplification strategies used in each of the four different protocols examined. The observation of intra-sample variation introduced by the choice of protocol highlights the role that external factors play in planning and subsequent reliable interpretation of results of any RNA-seq experiment.

Keywords: Library preparation; RNA purification; reverse transcription and cDNA amplification.

Publication types

  • Comparative Study
  • Research Support, N.I.H., Extramural
  • Research Support, N.I.H., Intramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Humans
  • Male
  • Sequence Analysis, RNA / methods*
  • Spermatozoa / metabolism*

Associated data

  • GEO/GSE57503