Tolerability of ambulatory blood pressure monitoring (ABPM) in cognitively impaired elderly

Blood Press. 2014 Dec;23(6):377-80. doi: 10.3109/08037051.2014.916064. Epub 2014 Jun 12.

Abstract

Objective: Recent guidelines have widened clinical indications for out-of-office blood pressure measurement, including home blood pressure monitoring and ambulatory blood pressure monitoring (ABPM), suggesting the latter as recommended method in cognitively impaired patients. There is, however, a widespread belief that ABPM could be poorly tolerated in dementia, often leading to withdraw from its use in these patients.

Aim: To assess the actual tolerability of ABPM in a group of cognitively impaired elderly, affected by dementia or mild cognitive impairment (MCI).

Methods: We evaluated 176 patients aged 65 + years, recruited in two different memory clinics, with a Mini Mental State Examination (MMSE) between 10 and 27. Behavioral and psychological symptoms were assessed with Neuropsychiatric Inventory (NPI). A patient was considered tolerant if able to keep the device on continuously for 24 h. The minimum number of correct measurements required was 70% of the predicted total number.

Results: 16% of patients wore the device for less than 24 h. Dividing the study population in tertiles of MMSE performance, 29% failed to tolerate the device in the lowest, 12% in the middle and 7% in the highest tertile (p < 0.01). Dividing the study population in tertiles of NPI performance, 30% of patients failed in the highest, 19% in the middle and 8% in the lowest tertile (p = 0.02); 31% of patients who tolerated the device did not achieve the minimum number of measurements required, with a mean number of 63% of predicted measurements.

Conclusion: The ABPM proved a generally well-tolerated technique even in cognitively impaired elderly. Only a minority of subjects with poorer cognitive performances and greater behavioral symptoms did not tolerate the monitoring. Among most patients who failed to achieve the minimum number of measurements needed, the number of valid measurements was very close to the minimum required.

Keywords: Ambulatory blood pressure monitoring; dementia; elderly; hypertension; mild cognitive impairment.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Age Factors
  • Aged
  • Aged, 80 and over
  • Blood Pressure
  • Blood Pressure Monitoring, Ambulatory / methods*
  • Cognition Disorders / complications
  • Cognition Disorders / diagnosis
  • Dementia / complications
  • Dementia / diagnosis
  • Female
  • Humans
  • Hypertension / complications
  • Hypertension / diagnosis*
  • Male