Graphical user interface for yield and dose estimations for cyclotron-produced technetium

Phys Med Biol. 2014 Jul 7;59(13):3337-52. doi: 10.1088/0031-9155/59/13/3337. Epub 2014 May 30.

Abstract

The cyclotron-based (100)Mo(p,2n)(99m)Tc reaction has been proposed as an alternative method for solving the shortage of (99m)Tc. With this production method, however, even if highly enriched molybdenum is used, various radioactive and stable isotopes will be produced simultaneously with (99m)Tc. In order to optimize reaction parameters and estimate potential patient doses from radiotracers labeled with cyclotron produced (99m)Tc, the yields for all reaction products must be estimated. Such calculations, however, are extremely complex and time consuming. Therefore, the objective of this study was to design a graphical user interface (GUI) that would automate these calculations, facilitate analysis of the experimental data, and predict dosimetry. The resulting GUI, named Cyclotron production Yields and Dosimetry (CYD), is based on Matlab®. It has three parts providing (a) reaction yield calculations, (b) predictions of gamma emissions and (c) dosimetry estimations. The paper presents the outline of the GUI, lists the parameters that must be provided by the user, discusses the details of calculations and provides examples of the results. Our initial experience shows that the proposed GUI allows the user to very efficiently calculate the yields of reaction products and analyze gamma spectroscopy data. However, it is expected that the main advantage of this GUI will be at the later clinical stage when entering reaction parameters will allow the user to predict production yields and estimate radiation doses to patients for each particular cyclotron run.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Computer Graphics*
  • Cyclotrons*
  • Gamma Rays
  • Radiochemistry / instrumentation*
  • Radiometry
  • Technetium / chemistry*
  • User-Computer Interface*

Substances

  • Technetium