[Transanal endoscopic microsurgery by transanal glove port combined with colonoscopy for excision of rectal tumors]

Zhonghua Wei Chang Wai Ke Za Zhi. 2014 May;17(5):473-5.
[Article in Chinese]

Abstract

Objective: To evaluate the feasibility and efficacy of transanal endoscopic microsurgery (TEM) by transanal glove port combined with colonoscopy for excision of rectal tumors.

Methods: Eight patients with rectal cancer eligible for local resection were chosen to receive a procedure performed via a "glove TEM port" from October 2012 to March 2013. This device was constructed on-table using a circular anal dilator (CAD), standard surgical glove, colonoscopy instruments and straight laparoscopic instruments.

Results: Procedures of all the patients were completed successfully by glove TEM. The median (range) diameter of tumor was 2.6(1.5-3.5) cm, the median (range) operative time was 55.6(30-110) min. Postoperative pathology included villous adenomas (n=3), tubular adenomas (n=2), tubulovillous adenomas (n=2), serrated adenoma (n=1), low-grade intraepithelial neoplasia (n=2), and high-grade intraepithelial neoplasia (n=1). All resection margins were negative. Two patients presented with postoperative minor bleeding. There were no serious intraoperative complications. No cancer recurrence was found during a follow-up of 1-5 (median 3.1) months.

Conclusion: Transanal endoscopic microsurgery by transanal glove port combined with colonoscopy in the treatment of early rectal cancer is easy and safe.

Publication types

  • English Abstract
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Colonoscopy / methods*
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Microsurgery / methods*
  • Middle Aged
  • Rectal Neoplasms / surgery*
  • Treatment Outcome