Silica removal in industrial effluents with high silica content and low hardness

Environ Sci Pollut Res Int. 2014;21(16):9832-42. doi: 10.1007/s11356-014-2906-8. Epub 2014 Apr 30.

Abstract

High silica content of de-inked paper mill effluents is limiting their regeneration and reuse after membrane treatments such as reverse osmosis (RO). Silica removal during softening processes is a common treatment; however, the effluent from the paper mill studied has a low hardness content, which makes the addition of magnesium compounds necessary to increase silica removal. Two soluble magnesium compounds (MgCl₂∙6H₂O and MgSO₄∙7H₂O) were tested at five dosages (250-1,500 mg/L) and different initial pH values. High removal rates (80-90%) were obtained with both products at the highest pH tested (11.5). With these removal efficiencies, it is possible to work at high RO recoveries (75-85%) without silica scaling. Although pH regulation significantly increased the conductivity of the waters (at pH 11.5 from 2.1 to 3.7-4.0 mS/cm), this could be partially solved by using Ca(OH)₂ instead of NaOH as pH regulator (final conductivity around 3.0 mS/cm). Maximum chemical oxygen demand (COD) removal obtained with caustic soda was lower than with lime (15 vs. 30%). Additionally, the combined use of a polyaluminum coagulant during the softening process was studied; the coagulant, however, did not significantly improve silica removal, obtaining a maximum increase of only 10%.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Hydrogen-Ion Concentration
  • Industrial Waste / analysis*
  • Magnesium / chemistry
  • Osmosis
  • Paper*
  • Silicon Dioxide / chemistry
  • Silicon Dioxide / isolation & purification*
  • Waste Disposal, Fluid / methods*

Substances

  • Industrial Waste
  • Silicon Dioxide
  • Magnesium