The putaminal abnormalities on 3.0T magnetic resonance imaging: can they separate parkinsonism-predominant multiple system atrophy from Parkinson's disease?

Acta Radiol. 2015 Mar;56(3):322-8. doi: 10.1177/0284185114524090. Epub 2014 Mar 11.

Abstract

Background: The putaminal abnormalities detected on 1.5 T magnetic resonance imaging (MRI), such as putaminal atrophy, slit-like hyperintense rim, and hypointensity in the putamen on T2-weighted (T2W) imaging are important signs on differentiating multiple system atrophy with parkinsonism (MSA-P) from Parkinson's disease (PD). However, the putaminal abnormalities may have different manifestations on 3.0 T from those on 1.5 T.

Purpose: To investigate the diagnostic value of putaminal abnormalities on 3.0 T MRI for differentiating MSA-P from PD.

Material and methods: The study included a MSA-P group (9 men, 9 women), a PD group (12 men, 14 women), and a control group (11 men, 13 women). All subjects were examined with 3.0 T MRI using the conventional protocol. Putaminal atrophy, T2-hypointensity in the dorsolateral putamenat, and a slit-like hyperintense rim on the lateral putamen were evaluated in each subject.

Results: There were no significant differences in the slit-like hyperintense rim (P = 0.782) or T2-hypointensity in the dorsolateral putamen (P = 0.338) among the three groups. Bilateral putaminal atrophy was found in 44.4% (8 of 18) of the MSA-P patients, in only 7.7% (2 of 26) of the PD patients, and in none of the controls. The proportion of subjects with putaminal atrophy was significantly higher in the MAS-P group (P = 0.008) and control group (P < 0.001). The specificity and sensitivity of putaminal atrophy for distinguishing MSA-P from PD was 92.3% and 44.4%, respectively.

Conclusion: The signal changes in the putamen on T2W imaging on 3.0 T MRI, including slit-like hyperintense rim and putaminal hypointensity, are not specific signs for MSA-P. Putaminal atrophy is highly specific for differentiating MSA-P from PD and healthy controls, but its insufficient sensitivity limits its diagnostic value.

Keywords: CNS; brain/brain stem; efficacy studies; magnetic resonance imaging (MRI).

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Analysis of Variance
  • Diagnosis, Differential
  • Female
  • Humans
  • Image Processing, Computer-Assisted / methods
  • Magnetic Resonance Imaging / methods*
  • Male
  • Multiple System Atrophy / diagnosis*
  • Parkinson Disease / diagnosis*
  • Parkinsonian Disorders / diagnosis
  • Putamen / abnormalities*
  • Putamen / pathology*
  • Reproducibility of Results
  • Sensitivity and Specificity