Mechanisms of pulmonary vein reconnection after radiofrequency ablation of atrial fibrillation: the deterministic role of contact force and interlesion distance

J Cardiovasc Electrophysiol. 2014 Jul;25(7):701-8. doi: 10.1111/jce.12396. Epub 2014 Apr 2.

Abstract

Introduction: Pulmonary vein reconnection (PVR) is an important cause of AF recurrence after ablation. With the advent of force sensing catheters, catheter-tissue contact can be determined quantitatively. Since contact force (CF) plays a major role in determining the characteristics of RF lesion, we prospectively assessed the mechanisms of PVR with regard to catheter-contact and lesion distances in patients undergoing AF ablation.

Methods and results: Forty symptomatic AF patients underwent wide circumferential PV isolation (PVI) with SmartTouch™ CF catheter. The exact locations of acute PVI and spontaneous or adenosine-provoked PVR were annotated on CARTO. One thousand nine hundred and twenty-six RF lesions isolated 153 PVs. PVR occurred in 35 (23%) PVs: 22 (63%) adenosine-provoked and 13 (37%) spontaneous. CF was significantly lower at PVR versus PVI sites for RF lesions within 6 mm from these sites: mean CF 5 versus 11 g (P < 0.0001) and force-time integral (FTI) 225 versus 415 gs (P < 0.0001); 86% of PVR occurred with a mean CF < 10 g (FTI < 400 gs); and the remaining 14% occurred at ablation sites with a long interlesion distance (≥5 mm) despite mean CF ≥ 10 g. Eighty percent of PVR sites were located anteriorly. There were no significant differences in regard to arrhythmia freedom between the patients without (69%) versus with PVR (67%; P = 1.0).

Conclusions: Acutely durable PVI can be achieved when RF lesions are delivered with a mean CF ≥ 10 g and an interlesion distance <5 mm. The majority of PVR occur anteriorly due to inadequate CF or long interlesion distances.

Keywords: adenosine; atrial fibrillation; catheter ablation; contact force; pulmonary vein isolation; pulmonary vein reconnection.

MeSH terms

  • Adenosine
  • Aged
  • Atrial Fibrillation / diagnosis
  • Atrial Fibrillation / physiopathology
  • Atrial Fibrillation / surgery*
  • Cardiac Catheterization / adverse effects*
  • Cardiac Catheterization / instrumentation
  • Cardiac Catheterization / methods
  • Cardiac Catheters
  • Catheter Ablation / adverse effects*
  • Catheter Ablation / instrumentation
  • Catheter Ablation / methods
  • Electrophysiologic Techniques, Cardiac
  • Equipment Design
  • Female
  • Humans
  • Male
  • Middle Aged
  • Prospective Studies
  • Pulmonary Veins / physiopathology
  • Pulmonary Veins / surgery*
  • Recurrence
  • Time Factors
  • Transducers, Pressure
  • Treatment Outcome

Substances

  • Adenosine