Hemodynamic impact and outcome of permanent pacemaker implantation following transcatheter aortic valve implantation

Am J Cardiol. 2014 Jan 1;113(1):132-7. doi: 10.1016/j.amjcard.2013.09.030. Epub 2013 Oct 4.

Abstract

Transcatheter aortic valve implantation (TAVI) frequently requires postprocedural permanent pacemaker (PPM) implantation. We evaluated clinical and hemodynamic impact of PPM after TAVI. Clinical and echocardiographic data were retrospectively analyzed in 230 consecutive patients who underwent TAVI and echocardiography at baseline and after 6 months. Echocardiographic parameters included left ventricular ejection fraction (LVEF), left ventricular (LV) stroke volume, early mitral velocity/annulus velocity ratio (E/e'), right ventricular index of myocardial performance, systolic pulmonary artery pressure (SPAP), and aortic, mitral, and tricuspid regurgitation grades. Clinical outcomes included 2-year survival and cardiovascular and PPM-related event-free survival. The Medtronic CoreValve and Edwards Sapien prosthesis were used in 201 and 29 patients, respectively. PPM was required in 58 patients (25.4%). Two-year and event-free survival rates were similar between patients with and without PPM. At 6 months, patients with PPM demonstrated attenuated improvement in LVEF (-0.9 ± 8.7% vs 2.3 ± 10.8%, respectively, p = 0.03) and LV stroke volume (-2 ± 16 vs 4 ± 10 ml/m(2), respectively, p = 0.015), a trend toward smaller reduction in systolic pulmonary artery pressure (-1 ± 12 vs -6 ± 10 mm Hg, respectively, p = 0.09), and deterioration of right ventricular index of myocardial performance (-3 ± 17% vs 5 ± 26%, respectively, p = 0.05). The differences in post-TAVI aortic, mitral, and tricuspid regurgitation grades were insignificant. In conclusion, PPM implantation after TAVI is associated with reduced LVEF and impaired LV unloading. However, this unfavorable hemodynamic response does not affect the 2-year clinical outcome. The maintenance of clinical benefit appears to be driven by TAVI-related recovery of LV and right ventricular performance that mitigates unfavorable impact of PPM.

Publication types

  • Comparative Study

MeSH terms

  • Aged, 80 and over
  • Aortic Valve Stenosis / complications
  • Aortic Valve Stenosis / physiopathology*
  • Aortic Valve Stenosis / surgery
  • Arrhythmias, Cardiac / etiology
  • Arrhythmias, Cardiac / physiopathology
  • Arrhythmias, Cardiac / therapy*
  • Cardiac Catheterization*
  • Disease-Free Survival
  • Echocardiography
  • Electrocardiography
  • Female
  • Follow-Up Studies
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Ventricles / diagnostic imaging*
  • Heart Ventricles / physiopathology
  • Hemodynamics / physiology*
  • Humans
  • Male
  • Pacemaker, Artificial*
  • Treatment Outcome