High-performance, low-voltage electroosmotic pumps with molecularly thin silicon nanomembranes

Proc Natl Acad Sci U S A. 2013 Nov 12;110(46):18425-30. doi: 10.1073/pnas.1308109110. Epub 2013 Oct 28.

Abstract

We have developed electroosmotic pumps (EOPs) fabricated from 15-nm-thick porous nanocrystalline silicon (pnc-Si) membranes. Ultrathin pnc-Si membranes enable high electroosmotic flow per unit voltage. We demonstrate that electroosmosis theory compares well with the observed pnc-Si flow rates. We attribute the high flow rates to high electrical fields present across the 15-nm span of the membrane. Surface modifications, such as plasma oxidation or silanization, can influence the electroosmotic flow rates through pnc-Si membranes by alteration of the zeta potential of the material. A prototype EOP that uses pnc-Si membranes and Ag/AgCl electrodes was shown to pump microliter per minute-range flow through a 0.5-mm-diameter capillary tubing with as low as 250 mV of applied voltage. This silicon-based platform enables straightforward integration of low-voltage, on-chip EOPs into portable microfluidic devices with low back pressures.

Keywords: MEMS; electrokinetics; lab-on-a-chip; microfluidics.

Publication types

  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Electromagnetic Fields
  • Lab-On-A-Chip Devices*
  • Membranes, Artificial*
  • Microfluidics / instrumentation*
  • Microfluidics / methods
  • Nanostructures / chemistry*
  • Osmotic Pressure*
  • Silicon / chemistry*

Substances

  • Membranes, Artificial
  • Silicon