PAT tools for the control of co-extrusion implants manufacturing process

Int J Pharm. 2013 Dec 15;458(1):15-24. doi: 10.1016/j.ijpharm.2013.09.040. Epub 2013 Oct 19.

Abstract

Hot melt extrusion is a novel pharmaceutical manufacturing process technique. In this study, we identified four Critical Quality Attributes (CQAs) of the implant manufacturing process by hot melt extrusion: the implant diameter, the quantity of the Active Pharmaceutical Ingredient (API), the homogeneity distribution of API and the thickness of the membrane. We controlled the implant diameter and the quantity of API in-line with a laser measurement, NIR and Raman spectroscopy, respectively. These two different spectroscopic techniques provided comparable results. In fact, the RMSEC and RMSECV were very close in each PAT technique but NIR spectroscopy was easier to use and less sensitive to external changes. For the control of the homogeneity of API distribution and the thickness of the membrane, we used successfully Raman spectroscopy imaging. These PAT tools help reducing analysis time.

Keywords: Hot melt extrusion; Implant; NIR spectroscopy; Process Analytical Technology; Raman imaging; Raman spectroscopy.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Chemistry, Pharmaceutical / methods*
  • Hot Temperature
  • Spectroscopy, Near-Infrared / methods
  • Spectrum Analysis, Raman / methods
  • Technology, Pharmaceutical / methods*