Abstract

Aim: The Severe Impairment Battery (SIB), a reliable cognitive measure for evaluating treatment response in advanced Alzheimer's disease (AD), takes approximately 20 min to administer. A recently derived 8-item version of the SIB - the SIB-8 - which takes about 3 min to administer, may represent a more convenient tool for use in clinical practice. The current analyses further explored the SIB-8 scale with respect to its validity and sensitivity.

Methods: A post hoc analysis was performed using data from a 24-week trial of donepezil 23 mg/day and 10 mg/day in > 1400 patients with moderate to severe AD [baseline Mini-Mental State Examination (MMSE) score 0-20]. Treatment effects on cognition (patterns of score change) were assessed using the full SIB and SIB-8 in the total study population and subgroups based on concomitant memantine use and baseline MMSE. Internal consistency/agreement and correlations between the SIB and SIB-8 and other clinical end points were evaluated.

Results: Assessment of score changes from baseline to week 24 with donepezil (23 or 10 mg/day) demonstrated comparable patterns of change when using the SIB-8 and the full SIB, despite inherent differences in the total score ranges for the two scales. Internal consistency/agreement between the full SIB and SIB-8 was good (Cronbach's alphas: 0.77-0.95). SIB-8 scores reliably correlated with SIB total scores (r = 0.859, baseline; r = 0.900, week 24; p < 0.0001), as well as MMSE scores (r = 0.7163, baseline; r = 0.7963, week 24; p < 0.0001). Scores on both SIB scales were moderately associated with functional measures at baseline and week 24.

Conclusions: In this post hoc analysis, similar treatment effects were measured by the full SIB and the SIB-8. Very good internal consistency/agreement and strong correlations between the SIB and the more rapid and convenient SIB-8 indicate that the SIB-8 may be a useful and efficient clinical proxy for the full SIB in evaluating treatment response in patients with advanced AD.

Trial registration: ClinicalTrials.gov NCT00478205.

Publication types

  • Comparative Study
  • Randomized Controlled Trial
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Activities of Daily Living
  • Alzheimer Disease / drug therapy*
  • Analysis of Variance
  • Cognition Disorders / diagnosis
  • Donepezil
  • Double-Blind Method
  • Humans
  • Indans / administration & dosage*
  • Neuropsychological Tests / standards*
  • Nootropic Agents / administration & dosage*
  • Piperidines / administration & dosage*
  • Severity of Illness Index
  • Treatment Outcome

Substances

  • Indans
  • Nootropic Agents
  • Piperidines
  • Donepezil

Associated data

  • ClinicalTrials.gov/NCT00478205