Monitoring dry-curing of S. Daniele ham by magnetic resonance imaging

Food Chem. 2013 Dec 1;141(3):2246-52. doi: 10.1016/j.foodchem.2013.04.068. Epub 2013 May 9.

Abstract

S. Daniele hams were collected at different stages during dry-curing and submitted to magnetic resonance imaging (MRI) according to the acquisition Spin-Echo sequences T1 and T2. The intensity of the MR signals in the images of the Semimembranosus, Semitendinosus, Rectus femoris and Biceps femoris muscles of the hams was computed and expressed in grey levels. Muscles were also submitted to traditional analyses, including aw, soluble solids, sodium chloride, total and water soluble nitrogen. T1 and T2 MR signals well described the evolution of the phenomena occurring in the different muscles during dry-curing. MR signal acquired in T2 mode well correlated with traditional indicators in Semitendinosus, Rectus femoris and Biceps femoris muscles. Predictive models estimating the value of aw, moisture, salt content and proteolysis extent on the basis of the MR signal intensity were proposed.

Keywords: Dry-curing; MRI; Moisture; Predictive models; S. Daniele ham; Salt.

Publication types

  • Evaluation Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Animals
  • Food Handling*
  • Magnetic Resonance Imaging / methods*
  • Meat Products / analysis*
  • Muscle, Skeletal / chemistry
  • Swine