Evaluation of nonscarred myocardial T1 value using contrast-enhanced look-locker cardiac MRI and its relationship to cardiac function in dilated cardiomyopathy: Comparison of 1.5 and 3.0 Tesla MRI

J Magn Reson Imaging. 2013 Dec;38(6):1395-401. doi: 10.1002/jmri.24131. Epub 2013 Jul 12.

Abstract

Purpose: To assess relationship between nonscarred myocardial T1 value measured using contrast-enhanced Look-Locker MRI and cardiac function in dilated cardiomyopathy (DCM) at 1.5 Tesla (T) and 3.0T MRI.

Materials and methods: Contrast-enhanced Look-Locker MRI was performed in 35 DCM patients. Nonscarred myocardial and blood T1 values were calculated from the signal intensity values and the delay time obtained on Look-Locker MRI. We assessed the correlation between the myocardial T1 value or myocardial T1 minus blood T1 value and cardiac function estimated using cine MRI (e.g., end-diastolic volume: EDV, left ventricular ejection fraction: LVEF) or brain natriuretic peptide (BNP).

Results: With 1.5T MRI (n = 16), the myocardial T1 value correlated negatively with the EDV(r = -0.66) and end-systolic volume (ESV; r = -0.68), and positively with the LVEF (r = 0.51); the myocardial T1 minus blood T1 value correlated inversely with EDV (r = -0.70), ESV (r = -0.62), and brain natriuretic peptide (BNP; r = -0.56). With 3.0T MRI (n = 17), the myocardial T1 value correlated negatively with ESV (r = -0.44), septal thickness (r = -0.60), and BNP (r = -0.51), and positively with LVEF (r = 0.61); the myocardial T1 minus blood T1 value negatively correlated with BNP (r = -0.50) and positively with LVEF (r = 0.54).

Conclusion: The nonscarred myocardial T1 value measured with either 1.5T or 3.0T contrast-enhanced Look-Locker MRI is significantly related to cardiac dysfunction in DCM.

Keywords: 1.5T; 3.0T; Look-Locker imaging; T1 value; dilated cardiomyopathy; myocardium.

Publication types

  • Comparative Study
  • Randomized Controlled Trial

MeSH terms

  • Adult
  • Aged
  • Cardiomyopathy, Dilated / complications
  • Cardiomyopathy, Dilated / diagnosis*
  • Cardiomyopathy, Dilated / physiopathology*
  • Cicatrix / etiology
  • Cicatrix / pathology
  • Contrast Media
  • Female
  • Gadolinium*
  • Heart Function Tests*
  • Humans
  • Image Enhancement / methods*
  • Image Interpretation, Computer-Assisted / methods*
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Reproducibility of Results
  • Sensitivity and Specificity

Substances

  • Contrast Media
  • Gadolinium