Monitoring soil water content by vertical temperature variations

Ground Water. 2014 Jul-Aug;52(4):566-72. doi: 10.1111/gwat.12090. Epub 2013 Jul 8.

Abstract

The availability of high sensitivity temperature sensors (0.001 K sensitivity platinum resistors), which can be positioned at intervals of a few centimeters along a vertical profile in the unsaturated zone, allows short-term in situ determinations-one day or even less-of the thermal diffusivity. The development of high data storage capabilities also makes this possible over long periods and the relative variations in thermal diffusivity allow the monitoring of the variations in water content. The processing of temperature measurements recorded at different depths is achieved by solving the heat equation, using the finite elements method, with both conductive and convective heat transfers. A first set of measurements has allowed this approach to be validated. Water content variations derived from thermal diffusivity values are in excellent agreement with TDR measurements carried out on the experimental site at Boissy-le-Châtel (Seine et Marne, France).

MeSH terms

  • Environmental Monitoring / methods*
  • France
  • Soil / chemistry*
  • Temperature*
  • Thermometry*
  • Water / analysis*

Substances

  • Soil
  • Water