Foreign body pulmonary embolism

Wien Klin Wochenschr. 2013 Jun;125(11-12):337-8. doi: 10.1007/s00508-013-0375-6. Epub 2013 Jun 14.

Abstract

We report a case of a foreign body embolism caused by a tip of an explanted port-a-cath system. The embolus could be removed with a gooseneck snare catheter, the patient fully recovered.

Publication types

  • Case Reports

MeSH terms

  • Diagnosis, Differential
  • Female
  • Foreign Bodies / diagnosis
  • Foreign Bodies / etiology*
  • Foreign Bodies / surgery*
  • Humans
  • Middle Aged
  • Pulmonary Embolism / diagnosis
  • Pulmonary Embolism / etiology*
  • Pulmonary Embolism / surgery*
  • Treatment Outcome
  • Vascular Access Devices / adverse effects*