Management of fractured implant case using loop connector fixed partial denture

BMJ Case Rep. 2013 May 24:2013:bcr2013009858. doi: 10.1136/bcr-2013-009858.

Abstract

Dental implants treatment have become a common modality of treatment nowadays for the replacement of missing tooth/teeth, but there have been failures due to a number of reasons; one of the rare problems is the fracture of the dental implants fixture. It is of prime importance to understand the type/system of the implant to be placed in a site and the amount and direction of occlusal forces incurred after the loading of prosthesis.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Dental Implants*
  • Dental Restoration Failure*
  • Denture, Partial, Fixed*
  • Humans
  • Male
  • Radiography, Dental

Substances

  • Dental Implants