A new simplified technique for making tricuspid expanded polytetrafluoroethylene valved conduit for right ventricular outflow reconstruction

Ann Thorac Surg. 2013 May;95(5):e131-3. doi: 10.1016/j.athoracsur.2012.12.047.

Abstract

Several methods of making expanded polytetrafluoroethylene valved conduit have been reported, but these techniques are complicated and less reproducible. We have developed a new simplified technique for making a tricuspid expanded polytetrafluoroethylene valved conduit for right ventricular outflow tract reconstruction and have been using this conduit for approximately 3 years with excellent results. Our technique is straightforward and reproducible, and the cusps in the conduit are durable due to the use of a specialized suturing technique.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Child
  • Child, Preschool
  • Heart Valve Prosthesis*
  • Heart Ventricles / surgery*
  • Humans
  • Infant
  • Polytetrafluoroethylene*
  • Tetralogy of Fallot / surgery
  • Tricuspid Valve / surgery*
  • Ventricular Outflow Obstruction / surgery*

Substances

  • Polytetrafluoroethylene