Improvement of left ventricular longitudinal systolic function after transcatheter aortic valve implantation: a speckle-tracking prospective study

Int J Cardiovasc Imaging. 2013 Jun;29(5):1007-15. doi: 10.1007/s10554-012-0175-5. Epub 2012 Dec 28.

Abstract

Transcatheter aortic valve implantation (TAVI) is able to determine a significant improvement of left ventricular ejection fraction (LVEF). The variations of LV global longitudinal strain (GLS) have not been yet investigated in TAVI patients with reduced LVEF. The aim of this study was to determine the effects of TAVI on LV function by 2D speckle-tracking echocardiography (STE) in patients with reduced LVEF. Eighteen consecutive patients undergoing TAVI in our centre were prospectively enrolled. Echocardiography was performed pre-procedurally the day of TAVI and at 40-day and 3-month follow-up (FU). The mean age of TAVI patients was 79.75 ± 7.68 years. The mean EuroSCORE was 26.59 ± 14.62%. A significant decrease of mean trans-aortic gradient was observed 40 days after TAVI (51.69 ± 18.82 vs. 9.62 ± 3.28 mmHg, p < 0.0001). LV mass index significantly decreased at 40-day FU (165.72 ± 37.75 vs. 145.52 ± 31.32 g/m(2), p < 0.001) with a further reduction at 3-month FU (136.91 ± 26.91 g/m(2), p < 0.05 in comparison with 40-day FU). The mean pre-procedural LVEF was 45.87 ± 7.95%. LVEF significantly increased at 40-day FU (55.20 ± 5.91%, p < 0.05) and remained stable at 3-month FU (55.58 ± 6.14%). Interestingly, an early improvement of LV GLS was observed at 40-day FU (-11.09 ± 3.40 vs. -14.40 ± 3.68%, p < 0.001) with a slight further increase at 3-month FU (-14.71 ± 3.56%). Our results indicate that significant improvements of LVEF and LV GLS can be observed in patients undergoing TAVI with impaired LVEF. Two-dimensional STE was able to detect the reverse remodeling of LV function, adding further insights into the assessment of LV mid-term recovery after TAVI.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / therapy*
  • Cardiac Catheterization*
  • Echocardiography, Doppler*
  • Echocardiography, Doppler, Pulsed
  • Female
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Ventricles / diagnostic imaging*
  • Heart Ventricles / physiopathology*
  • Hemodynamics
  • Humans
  • Italy
  • Linear Models
  • Male
  • Multivariate Analysis
  • Predictive Value of Tests
  • Prospective Studies
  • Recovery of Function
  • Stroke Volume
  • Systole*
  • Time Factors
  • Treatment Outcome
  • Ventricular Function, Left*
  • Ventricular Remodeling