Comparison of reliability, validity, and responsiveness of the mini-BESTest and Berg Balance Scale in patients with balance disorders

Phys Ther. 2013 Feb;93(2):158-67. doi: 10.2522/ptj.20120171. Epub 2012 Sep 27.

Abstract

Background: Recently, a new tool for assessing dynamic balance impairments has been presented: the 14-item Mini-BESTest.

Objective: The aim of this study was to compare the psychometric performance of the Mini-BESTest and the Berg Balance Scale (BBS).

Design: A prospective, single-group, observational design was used in the study.

Methods: Ninety-three participants (mean age=66.2 years, SD=13.2; 53 women, 40 men) with balance deficits were recruited. Interrater (3 raters) and test-retest (1-3 days) reliability were calculated using intraclass correlation coefficients (ICCs). Responsiveness and minimal important change were assessed (after 10 sessions of physical therapy) using both distribution-based and anchor-based methods (external criterion: the 15-point Global Rating of Change [GRC] scale).

Results: At baseline, neither floor effects nor ceiling effects were found in either the Mini-BESTest or the BBS. After treatment, the maximum score was found in 12 participants (12.9%) with BBS and in 2 participants (2.1%) with Mini-BESTest. Test-retest reliability for total scores was significantly higher for the Mini-BESTest (ICC=.96) than for the BBS (ICC=.92), whereas interrater reliability was similar (ICC=.98 versus .97, respectively). The standard error of measurement (SEM) was 1.26 and the minimum detectable change at the 95% confidence level (MDC(95)) was 3.5 points for Mini-BESTest, whereas the SEM was 2.18 and the MDC(95) was 6.2 points for the BBS. In receiver operating characteristic curves, the area under the curve was 0.92 for the Mini-BESTest and 0.91 for the BBS. The best minimal important change (MIC) was 4 points for the Mini-BESTest and 7 points for the BBS. After treatment, 38 participants evaluated with the Mini-BESTest and only 23 participants evaluated with the BBS (out of the 40 participants who had a GRC score of ≥ 3.5) showed a score change equal to or greater than the MIC values.

Limitations: The consecutive sampling method drawn from a single rehabilitation facility and the intrinsic weakness of the GRC for calculating MIC values were limitations of the study.

Conclusions: The 2 scales behave similarly, but the Mini-BESTest appears to have a lower ceiling effect, slightly higher reliability levels, and greater accuracy in classifying individual patients who show significant improvement in balance function.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't
  • Validation Study

MeSH terms

  • Aged
  • Central Nervous System Diseases / physiopathology*
  • Central Nervous System Diseases / rehabilitation*
  • Disability Evaluation*
  • Female
  • Humans
  • Male
  • Physical Therapy Modalities*
  • Postural Balance / physiology*
  • Prospective Studies
  • Psychometrics
  • ROC Curve
  • Reproducibility of Results