Percutaneous evacuation of diffuse pulmonary interstitial emphysema by lung puncture in a baby with extremely low birth weight: a case report

J Med Case Rep. 2012 Sep 26:6:325. doi: 10.1186/1752-1947-6-325.

Abstract

Introduction: Pulmonary interstitial emphysema is a serious complication of mechanical ventilation and can become life-threatening if progression occurs. Therapeutic lung puncture is a treatment option for severe pulmonary interstitial emphysema but has a limited use in babies with extremely low birth weight. We present a case of pulmonary interstitial emphysema in a Japanese baby (1-day-old) boy with extremely low birth weight. The emphysema was successfully decompressed by therapeutic lung puncture performed with a trocar catheter.

Case presentation: The baby was born with a weight of 420g, which, to the best of our knowledge, is the lowest reported birth weight among babies with pulmonary interstitial emphysema. A chest X-ray on postnatal day 2 revealed pulmonary interstitial emphysema, which gradually progressed to diffuse pseudocystic changes. His condition became life-threatening despite the use of high-frequency oscillatory ventilation and lateral decubitus positioning. We evacuated the pulmonary interstitial emphysema by lung puncture with a trocar catheter to avoid respiratory and cardiovascular collapse. This resulted in adequate evacuation of the emphysema and a dramatic improvement in his clinical condition.

Conclusions: Therapeutic lung puncture performed with a trocar catheter is beneficial in babies with extremely low birth weight and diffuse pulmonary interstitial emphysema. This treatment option may be broadly applicable, especially in an emergency situation.