Use of Bio-Amp, a commercial bio-additive for the treatment of grease trap wastewater containing fat, oil, and grease

Bioresour Technol. 2012 Nov:124:52-8. doi: 10.1016/j.biortech.2012.08.012. Epub 2012 Aug 10.

Abstract

This research investigated the application of Bio-Amp, a commercial bio-additive for the treatment of fat, oil, and grease (FOG) in a grease trap, and evaluated potential impacts of treated effluent on downstream collection system and treatment processes. Results show that after Bio-Amp treatment, FOG deposit formation was reduced by 40%, implicating a potential reduction of sewer line blockages. Chemical oxygen demand (COD), total nitrogen (TN), total phosphorus (TP) and total fatty acids were reduced by 39%, 33%, 56%, and 59%, respectively, which represents an overall loading reduction of 9% COD, 5% TN and 40% TP received by the treatment plant from all the dining halls. On the other hand, readily biodegradable COD fractions significantly increased, which implies a potential improvement on Bio-P removal. Overall, the results showed that application of Bio-Amp in grease trap provides potential reduction of sewer line blockages, and can also alleviate downstream treatment burden.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Environmental Restoration and Remediation / methods*
  • Fats / analysis*
  • Oils / analysis*
  • Wastewater / chemistry*

Substances

  • Fats
  • Oils
  • Waste Water