Description of high purity and high specific activity of [11C]Choline synthesis using TRACERlab FXc module, and detailed report of quality controls

Med Chem. 2012 Nov;8(6):1182-9. doi: 10.2174/1573406411208061182.

Abstract

We proposed a method of synthesis to produce [11C]Choline using TRACERlab FXc module that utilized gas phase iodination. The product had radiochemical purity of 99.79 ± 0.14 % and specific activity of 45.7 ± 7.59 GBq/μmol. [11C]Choline did not have at the moment a specific monograph in European Pharmacopeia therefore we used, when possible, as quality controls reference the monograph of [18F]FDG and we proposed suitable methods to verify radiochemical purity and to quantify residual DMAE and choline amounts.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Carbon Radioisotopes
  • Chemistry Techniques, Synthetic / instrumentation*
  • Chemistry Techniques, Synthetic / standards
  • Choline / chemical synthesis*
  • Choline / chemistry
  • Drug Stability
  • Endotoxins / analysis
  • Gases / chemistry
  • Halogenation
  • Hydrogen-Ion Concentration
  • Osmolar Concentration
  • Quality Control
  • Radiochemistry / instrumentation*
  • Radiochemistry / standards
  • Solvents / chemistry

Substances

  • Carbon Radioisotopes
  • Endotoxins
  • Gases
  • Solvents
  • Choline