Pyrolysis products of linear alkylbenzenes--implications in fire debris analysis

J Forensic Sci. 2013 Jan;58(1):210-6. doi: 10.1111/j.1556-4029.2012.02194.x. Epub 2012 May 18.

Abstract

In this case report, potential interferences from an improvised fire-extinguishing agent, a dishwashing liquid, containing linear alkylbenzene sulfonates (LAS), was studied. The presence of linear alkylbenzenes (LABs) in the fire debris sample was identified from the summed ion profile (SIP) analysis. It was found that the LAS from dishwashing liquids produce LABs by thermal degradation. Direct pyrolysis of a LAS-containing dishwashing liquid at 300°C yielded a distribution of LABs in the SIP. LABs began to break down at pyrolysis temperatures between 450 and 500°C and completely break down by 800°C. Observed pyrolysis breakdown products of LABs included toluene, ethylbenzene, meta-, para-, and ortho-xylenes, propylbenzene, indane, naphthalene, and 1- and 2-methylnaphthalenes. These data suggested the presence of LABs in fire debris evidence might complicate subsequent analysis because their breakdown products contained some of the target compounds common to ignitable liquid identification. Therefore, a positive determination of the presence of foreign ignitable liquids should be carefully evaluated when there is a presence of LABs in the SIP.