Manganese chloride tetrahydrate (CMC-001) enhanced liver MRI: evaluation of efficacy and safety in healthy volunteers

MAGMA. 2012 Oct;25(5):361-8. doi: 10.1007/s10334-012-0307-x. Epub 2012 Mar 8.

Abstract

Object: To evaluate the efficacy of three dose levels of the oral hepatobiliary manganese-based magnetic resonance imaging (MRI) contrast agent CMC-001, and assess its safety profile and patient acceptability.

Materials and methods: After ethics committee approval, 32 healthy volunteers (males/females: 18/14) were included. Liver MRI was performed before and 3 h after ingestion of 0.8, 0.4, and 0.2 g of CMC-001 on separate occasions. Liver-to-muscle signal intensity (SI) ratio from baseline to post-contrast and image quality was assessed. Adverse drug reactions/adverse events (ADRs/AEs) and clinico-laboratory tests were monitored.

Results: The increase in liver-to-muscle SI ratio was significantly higher after 0.8 g (0.696) compared to 0.4 g (0.458) and 0.2 g (0.223) (in all pair-wise comparisons, P < 0.0001). The overall image quality was superior after 0.8 g. ADRs/AEs were dose-related and predominantly of mild intensity.

Conclusion: Liver MRI using 0.8 g CMC-001 has the highest efficacy and still acceptable ADRs and should therefore be preferred.

Publication types

  • Clinical Trial, Phase II
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Contrast Media / pharmacology
  • Cross-Over Studies
  • Dose-Response Relationship, Drug
  • Double-Blind Method
  • Female
  • Humans
  • Imaging, Three-Dimensional / methods
  • Liver / pathology*
  • Magnetic Resonance Imaging / methods*
  • Male
  • Manganese / chemistry
  • Manganese / pharmacology*
  • Middle Aged
  • Muscles / pathology
  • Safety

Substances

  • CMC-001
  • Contrast Media
  • Manganese